Mobile Digital C Arm System With Digital Workstation Medical Radiology C-ARM Equipment Price for Sale

Electric power
a) Maximum output power for photography: 8kW (80kV, 100mA);
b) Maximum output power for perspective: 480W (120kV, 4mA);
c) Nominal power: 6kW for photography (100kV, 60mA, 6.3mAs).
Loading factors and control
1 Tube voltage
a) Range: 40kV~120kV, continuous adjustment; adjustment step 1, 10kV;
b) Deviation: ≤8%.
2 Continuous tube current
a) Adjust to 1mA, 2mA, 3mA, 4mA;
b) Deviation: ≤20%.
3 Photographic current-time product
a) Divided into 45 levels according to the R’20 number system, range: 1-160 mAs, linked with the photographic tube voltage and tube current for thermal capacity protection, kV allowable range: 40~120;
b) Deviation: ≤±(10%+0.2mAs).
Imaging performance
The incident field is 22.7cm×22.7cm, under the nominal incident field:
a) Under the test phantom, the spatial resolution of photography is not less than 2.4Lp/mm, and the spatial resolution of perspective is not less than 2.2Lp/mm;
b) Low contrast resolution: perspective is not more than 4%, photography is not more than 4%;
c) Dynamic range: the number of dynamic wedges that can be distinguished in perspective is not less than 16, and photography is not less than 16;
d) SID is 1m loading condition 80kV, 4mA perspective, flat panel detector image uniformity is not more than 2.2﹪;
e) Image brightness stability during automatic perspective should not be greater than 15﹪;
f) Perspective and photographic imaging time is not more than 500ms;
g) Automatic perspective image stabilization time should not be more than 2s;
h) Perspective recovery time is not more than 5min;
i) There are no artifacts that affect clinical application.
i) It can be used for pediatric examinations, with additional 4mm pure aluminum filters and anti-scattering filter grids that can be removed and installed without tools.
2.6
1 C-arm sliding
a) Sliding along the track in an arc, the stroke is not less than +90°~-25°, with a scale indication, and the deviation is ≤2°;
b) Sliding is manually operated, with a locking devi
Availability:
Quantity:
  • D037E-A

  • Mayamed

Previous: 
Next: 
Contact our customer service: nancy@medicalequipment168.com
+86-189-2504-4116

Product Category

Product Category

Maya

Solutions

Copyright © 2024 Guangzhou Maya Medical Equipment Co., Ltd. All Rights Reserved. Sitemap | Privacy Policy
Leave a Message
Free Consultation